Products list Itinerant Temperature Detector

XMZA-J838

Author: admin Viewed: 304Close

2018-06-21 15:36:59

  • XMZA-J838
  • XMZA-J838

Shape size:96mm(wide)*96mm(high)*120mm

Ⅰ、Survey

XMZ*-J series all-purpose input temperature patrol measure meter is a intelligent meter which adopt computer technology . the meter adopt two row LED, and at the same time distinguish display test temperature value and the present passage ,can use by automatic or manual to carry out tour test , and each passage have relative indicate light .It has computer RS485 serial-port communication ,or timed print.

Ⅱ、Main Technical Indexes:

1、Accuracy:±0.5%F·S±1B       

2、Input signal: K   E    J  R  S  Pt100   Cu50

3、Temperature:K(-30~1300℃)   E(-30~800℃)      

J(-30~1000℃)      R(-30.0~1700.0℃)    S(0~1600℃)

Pt100(-200.0~600℃)  Cu50(-50.0~150.0℃)

4、Passage quantity:at most 16 

5、Alarm relay contact capacity:220V 5A(resistance)    

6、External dimension and installation hole(mm):

XMZ-J   160×80×120     156×76

XMZA-J   96×96×110      92×92

6、Working power:AC220V±10%  50HZ,power consumption is less than 5W

7、Normal working condition :temperature 0~50℃,relative humidity 35%~85%,without corrode gas.

Ⅲ、Meaning of the model code

The meter is a all-purpose patrol measure meter for 1-16way,it is set when it is leaving the factory         

             XMZ□ -  J   □    □  8  □

                 1         2    3   4   5   

“1”:the surface dimension (mm):A:96×96×110  Installation hole:92×92     

Blank:160×80×120  Installation hole:152×76

“2”:Channel number:for example‘16’as 16 channels,‘8’as 8 channels.

“3”:Alarm definition:‘0’no alarm,‘1’upper limit alarm,‘2’lower limit alarm,‘3’upper and lower limit alarm

“4”:Input signal:‘8’kinds of signal input 

“5”:Suffix:‘WT’ with miniature printer,‘K’ with 485 communication model

‘Blank’ not have this function.