Products list Farms hatch

XMT-618 (N) (exclusively for hatchery incubation)

Author: admin Viewed: 291Close

2018-06-12 12:54:42

  • XMT-618 (N) (exclusively for hatchery incubation)
  • XMT-618 (N) (exclusively for hatchery incubation)

Shape size:160mm(wide)*80mm(high)*48mm

Ⅰ、Survey

Thanks for your selection of our XMT*608 series intelligent temperature controller.

XMT*608 series intelligent temperature controller,is double row 3LED display, respectively display  temperature measurement value (PV) and temperature set value (SV) under normal mode;When it is time temperature control, respectively display temperature measurement value (PV) and running time count down (SV),and also provide kinds of time control method selection;The controller can input kinds of signal which are used interchangeably,it adopt ON/OFF(P=0)PID control,allowing an easy parameter setting and convenient inputting,is widely used over temperature automatic control systems of machinery、chemicalceramicslight industrialmetallurgypetrifaction and heat treatment and so on.

Ⅱ、Main technical Indexes

1、 Measurement deviation:±0.5F·S±1additional cold end compensating deviation±1

2、 Input(can be selected):CU50(-50150)PT100(-80600)、K(-30999)、E(-30700)、

J(-30900)、T(199400)

3、 Relay output (passive) contact capacity:  

                      AC250V 5A(resistance load)    period 2~120s can be adjusted.

4、 Time range:0999s or 0999m(can be selected)

5、 Driving solid relay signal output:Driving electric current 15mA  no-load voltage12Vperiod is about 2S.

6、 Work power:110V242V50HZ    Power consumption3W

        7、Work environment:050℃,relative humidity85%,without corrode and strong electric radiation

Ⅲ、Meaning of the model code

                   XMT □— 6         □     8        

                    1   2     3     4     5     

1: the external dimension 

Blank:  160×80×85    Installation hole 156×76      

   A:  96×96×80      Installation hole 92×92

       D:  72×72×80     Installation hole 68×68        

   E:  48×96×75     Installation hole 44×92

   F:  96×48×75     Installation hole 92×44         

   G:  48×48×110    Installation hole 44×44

   S:  80×160×85    Installation hole 76×156        

   B60×120×90    Installation hole 56×116

   L:Standard DIN35mm guide way installation             

   C:80×120×35   wall set installation 

2: Operation display method:6’ 3-key gentle push-switch settingdouble row 3-LED digital displayPID control.

   3:Additional alarm:

0  no alarm;   

  1  upper limit alarm(upper deviation alarm when it is time temperature control) 

  4:Input: ‘8 input signal can interchange free(no voltage and current input)

     5:Suffix   Blank:relay output         G:solid relay output          T:Time control function


Support: 7277