Products list Current Display Instrument

DLA-30 Series Ammeter

Author: admin Viewed: 317Close

2018-06-12 13:07:40

  • DLA-30 Series Ammeter
  • DLA-30 Series Ammeter

Shape size: 96mm×48mm×75mm, Open hole: 92mm×44mm

Ⅰ、Survey:

D series intellective electric meter(Digital Ammeter、Digital Voltmeter、Frequency Meter、Tachometerand so on)is a type of multifunctional composite type meter, it apply to electric power and electric network, field monitoring and display of automatic control systems and remote control and measurement of automatic dispatch telemechanical device,its function is to output standard current or voltage transfer signal using CPU operation electric network’s parameter, such as current、voltage、3 phase power、frequency and so on,and then A/D’s conversion. Also this meter has RS232 or RS485 communication interface be joined with long range data terminal TRU.

Ⅱ、Main technical specification

1、Accuracy Class:0.5%F·S±1B
2、Display Digit:4
3、Reference Input:AC /AV:0~5A/0~500V  volts D.C.:0~199.9V  0~1000V
4、Power consumption:≤3W
5、Working power:AC85~242V,50/60HZ
6、Working circumstance:0~50℃,relative humidity≤85%,without corrode and electric radiation

Ⅲ、Panel board and connection

1、Panel board

The panel board function of each model can follow the above drawing.

2、connection

Ⅳ、Operation

1、Interior parameter(onlyCurrent、Voltage model meter have this parameter)

Series

Attention

Name

Setting range

Manual

Remarks

0

LocK

Electronic lock

0~255

Lock=18,all the parameter can be Revised. 

18

 

1

 

dP

 

Display precision

 

0~3

dp=0,the decimal doesn’t display

dp=1,the decimal in tens

dp=2,the decimal in hundreds

dp=3,the decimal in thousands

 

0

2

dIH

Set upper limit

Setting range determined by dp:is in turn 9.999、

99.99、999.9、9999

2、Operational flowchart:

3、connect according to the connection, the instrument will test by itself for 1S.

4、Interior parameter setting(parameter definition refer to parameter sheet)Press SET key for 3S to enter theInterior parameter setting state,it display parameter code first,and then display parameter value after 2s,press▲、▼to modify parameter value,and press SET to save and enter the next parameter setting ,exit till the setting finished. If not press any key ,it will save and exit automatically.

5、★current、voltage mode:if the meter display has warp,you can press ‘SET’&▲&▼key at one time to clear.(please be cautious to use this function).

Ⅴ、Meaning of the model code

D□ □-□  □  □-□

①  ②   ③   ④    ⑤    ⑥    

①:Series number L:Current model Y:Voltage model  F-frequency  R-revolving speed

②:External dimension and Installation hole(mm):

T:160×80×85 156×76      A:96×96×90   92×92     D:72×72×90   68×68
E:48×96×75   44×92      F:96×48×75   92×44      G:48×48×105  44×44

③:3-key soft push-switch setting, single row digital display,

④: Control output:
0: No alarm
1: A alarm
3: Two alarms
4: PID bit control
5: PID solid-state control
6: PID SCR phase shifter control
7: PID SCR zero-crossing control
8: SCR three-phase zero-crossing control
9: 4 ~ 20mA control output

⑤: The input nominal value:
No: AC current 5A input, the AC current for 0-9999 arbitrary setting, apply to all transformer      ammeter;  AC voltage for 0-500.0VAC;  

10: 0 ~ 10A 400: 0 ~ 400V 0.2: 0 ~ 200mA

⑥: Suffix: K- RS485 communication function

Ⅵ、Fault Analysis and Clearance

Sheet6-1Common fault handling

fault symptom

analysis of causes

Disposal measurement

The power on is unusual

1、poor contact of power cord 

2、power switch without lose

Check the power

Signal display do not correlate with the facts.(display‘HH’or‘0’)

1、Input nominal value overtop or under the meter’s display range

Check the input value

Support: 7277