DLF Series Ammeter
Author: admin Viewed: 480【Close】
2018-06-12 13:08:33
Shape size: 96mm×48mm×75mm, Open hole: 92mm×44mm
Ⅰ、Survey:
D series intellective electric meter(Digital Ammeter、Digital Voltmeter、Frequency Meter、Tachometerand so on)is a type of multifunctional compositetype meter, it apply to electric power and electric network, field monitoringand display of automatic control systems and remote control and measurement ofautomatic dispatch telemechanical device,its function is to output standard current or voltage transfer signal using CPU operation electricnetwork’s parameter, such as current、voltage、3 phase power、frequency and so on,and then A/D’s conversion. Also this meter has RS232 or RS485communication interface be joined with long range data terminal TRU.
Ⅱ、Main technical specification
1、Accuracy Class:0.5%F·S±1B
2、Display Digit:4
3、Reference Input:AC /AV:0~5A/0~500V volts D.C.:0~199.9V 0~1000V
4、Power consumption:≤3W
5、Working power:AC85~242V,50/60HZ
6、Working circumstance:0~50℃,relative humidity≤85%,without corrode and electric radiation
Ⅲ、Panel board and connection
1、Panel board
The panel board function of each model can follow the above drawing.
2、connection
Ⅳ、Operation
1、Interior parameter(onlyCurrent、Voltage model meter have this parameter)
Series | Attention | Name | Setting range | Manual | Remarks |
0 | LocK | Electronic lock | 0~255 | Lock=18,all the parameter can be Revised. | 18 |
1 |
dP |
Display precision |
0~3 | dp=0,the decimal doesn’t display dp=1,the decimal in tens dp=2,the decimal in hundreds dp=3,the decimal in thousands |
0 |
2 | dIH | Set upper limit | - | Setting range determined by dp:is in turn 9.999、 99.99、999.9、9999 | - |
2、Operational flowchart:
3、connect according to the connection, the instrument will test by itselffor 1S.
4、Interior parameter setting(parameter definition refer to parameter sheet)Press SET key for 3S to enter theInterior parameter setting state,it displayparameter code first,and then display parameter value after 2s,press▲、▼to modifyparameter value,and press SET to save and enter the next parameter setting ,exit tillthe setting finished. If not press any key ,it will save and exit automatically.
5、★current、voltage mode:if the meter display has warp,you can press ‘SET’&▲&▼key at one time toclear.(please be cautiousto use this function).
Ⅴ、Meaning of the model code
D□ □-□ □ □-□
① ② ③ ④ ⑤ ⑥
①:Seriesnumber L:Current model Y:Voltagemodel F-frequency R-revolving speed
②:External dimension and Installation hole(mm):
T:160×80×85 156×76 A:96×96×90 92×92 D:72×72×90 68×68
E:48×96×75 44×92 F:96×48×75 92×44 G:48×48×105 44×44
③:3-key soft push-switch setting, single row digitaldisplay,
④: Control output:
0: No alarm
1: A alarm
3: Two alarms
4: PID bit control
5: PID solid-state control
6: PID SCR phase shifter control
7: PID SCR zero-crossing control
8: SCR three-phase zero-crossing control
9: 4 ~ 20mA control output
⑤: The input nominal value:
No: AC current 5A input, the AC current for 0-9999 arbitrary setting, apply toall transformer ammeter; AC voltage for 0-500.0VAC;
10: 0 ~ 10A 400: 0 ~ 400V 0.2: 0 ~ 200mA
⑥: Suffix: K- RS485 communicationfunction
Ⅵ、Fault Analysis and Clearance
Sheet6-1Common fault handling
fault symptom | analysis of causes | Disposal measurement |
The power on is unusual | 1、poor contact of power cord 2、power switch without lose | Check the power |
Signal display do not correlate with the facts.(display‘HH’or‘0’) | 1、Input nominal value overtop or under the meter’s display range | Check the input value |